Initial start up and operation
Version 3.0 (08/2018)
Translation of original instruction manual 37
Under Voltage Error
Supply voltage too low:
Ignore: Error is not displayed.
Warning: Error is indicated by fault LED flashing five times.
The conveying process is not interrupted.
Immediate Stop: Error is indicated by fault LED flashing five times.
The conveying process is interrupted.
Motor Error
Engine monitoring:
Ignore: Error is not displayed.
Warning: Error is indicated by fault LED flashing three times.
If the error is no longer present, the LED goes out. Other motors
connected to the MultiControl rotate.
Immediate Stop: Error is indicated by fault LED flashing three times.
Other motors connected to the MultiControl stop.
General Control Error
Controller monitoring:
Ignore: Error is not displayed.
"Immediate Stop" and "Normal Stop" have the same behaviour.
The settings of Control Error 1 - 8 have no function.
To apply the changed parameters to the MultiControl, press the "Submit" button.
Changes only become effective after switching the controller off / on.