Troubleshooting
Version 3.0 (08/2018)
Translation of original instruction manual 49
Power
Ready
Net
Run
Fault
Meaning
Priority
-
-
-
Flashes
6 x
Voltage error overvoltage
4
-
-
-
Flashes
7 x
Temperature in the MultiControl
too high.
6
-
-
-
Flashes
8 x
Overload protection of the
brake chopper resistor active.
7
-
-
-
Flashes
9 x
Handshake communication
disturbed. See the instructions
for ZPA and ZPA + applications.
-
-
-
Flashes
10 x
No connection to the neighbour.
See the instructions for ZPA and
ZPA + applications
Flashes
10 x
A configured neighbour has an
error (see ZPA+,
"RemoteEmergency" in the error
log)
If several errors occur at the same time, only the highest priority error is displayed.
Troubleshooting see "Troubleshooting", page 50.

Table of Contents

Other manuals for Interroll MultiControl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interroll MultiControl and is the answer not in the manual?

Interroll MultiControl Specifications

General IconGeneral
Power Supply24 VDC
Rated Voltage24 VDC
Storage Temperature-20 °C to +70 °C
Communication ProtocolsEthernet/IP, PROFINET, EtherCAT, CANOpen
Number of Channels4
Weight0.5 kg