Goodrive35 inverters Function codes
103
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
right to left.
3: Shift between forward rotations and reverse
rotations. Press QUICK/JOG to shift the direction of
the frequency commands. This function is only valid
in the keypad commands channels.
4: Clear UP/DOWN settings. Press QUICK/JOG to
clear the set value of UP/DOWN.
5: Coast to stop. Press QUICK/JOG to coast to stop.
6: Shift the given manner of running commands.
Press QUICK/JOG to shift the given manner of
running commands.
7:Quick commission mode(committee according to
the non-factory parameter)
Note: Press QUICK/JOGto shift between forward
rotation and reverse rotation, the inverter does not
remember the state after shifting during powering
off. The inverter will run in the running direction set
according to parameter P00.13 during next powering
on.
P07.03
Shifting
sequence
selection
of
QUICK/JO
G
commands
When P07.06=6, set the shifting sequence of
running command channels.
0:Keypad controlterminals control
communication control
1:Keypad control←→terminals control
2:Keypad control←→communication control
3:Terminals control←→communication control
0
P07.04
STOP/RS
T stop
function
STOP/RST is valid for stop function. STOP/RST is
valid in any state for the fault reset.
0:Only valid for the keypad control
1:Both valid for keypad and terminals control
2:Both valid for keypad and communication control
3:Valid for all control modes
0