Goodrive35 inverters Function codes
128
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
time of
step 5
When terminal 1, terminal 2, terminal 3, terminal
4=OFF, the frequency input manner is selected via
code P00.06 or P00.07. When terminal 1, terminal 2,
terminal 3, terminal 4 arent off, it runs at multi-step
which takes precedence of keypad, analog value,
high-speed pulse, PLC, communication frequency
input.
The relationship between terminal 1, terminal 2,
terminal 3, terminal 4 and multi-step speed is as
following:
Terminal 1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Terminal 2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Terminal 3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Terminal 4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Step
0
1
2
3
4
5
6
7
Terminal 1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Terminal 2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Terminal 3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Terminal 4
ON
ON
ON
ON
ON
ON
ON
ON
Step
8
9
10
11
12
13
14
15
P10.14
Multi-step
speed 6
0.0%
P10.15
The
running
time of
step 6
0.0s
P10.16
Multi-step
speed 7
0.0%
P10.17
The
running
time of
step 7
0.0s
P10.18
Multi-step
speed 8
0.0%
P10.19
The
running
time of
step 8
0.0s
P10.20
Multi-step
speed 9
0.0%
P10.21
The
running
time of
step 9
0.0s
P10.22
Multi-step
speed 10
0.0%
P10.23
The
running
time of
0.0s
www.barghmaher.ir