Goodrive35 inverters Function codes
127
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
running
time of
step 0
The operation time setting of stage 0~15: the time
unit is determined by P10.37. When selecting simple
PLC running, set P10.02~P10.33 to define the
running frequency and time of all stages.
Note: The symbol of multi-step determines the
running direction of simple PLC. The negative value
means reverse rotation.
If multi-step speed operation is selected, multi-step
speeds are in the range of --f
max
~f
max
and it can be
set continuously.
Goodrive35 series inverters can set 16 stages
speed, selected by the combination of multi-step
terminals 1~4(select the setting by S terminals, the
corresponding function codes are P05.01~P05.09),
corresponding to the speed 1 to speed 15.
P10.04
Multi-step
speed 1
0.0%
P10.05
The
running
time of
step 1
0.0s
P10.06
Multi-step
speed 2
0.0%
P10.07
The
running
time of
step 2
0.0s
P10.08
Multi-step
speed 3
0.0%
P10.09
The
running
time of
step 3
0.0s
P10.10
Multi-step
speed 4
0.0%
P10.11
The
running
time of
step 4
0.0s
P10.12
Multi-step
speed 5
0.0%
P10.13
The
running
0.0s