Goodrive35 inverters Basic operation instruction
176
Function
code
Name
Detailed instruction of parameters
Default
value
synchronous motor 1
on model
P05.01~P0
5.09
Multi-function digital input
terminals
(S1~S8,HDI) function
selection
36:Shift the command to keypad
37:Shift the command to terminals
38:Shift the command to communication
P07.01
Parameter copy
The function code determines the
manner of parameters copy.
0:No operation
1:Upload the local function parameter to
the keypad
2:Download the keypad function
parameter to local address(including the
motor parameters)
3:Download the keypad function
parameter to local address (excluding the
motor parameter of P02 and P12 group)
4:Download the keypad function
parameters to local address (only for the
motor parameter of P02 and P12 group)
0
P07.02
QUICK/JOG function
selection
0: No function
1: Jogging. Press QUICK/JOG to begin
the jogging running.
2: Shift the display state by the shifting
key. Press QUICK/JOGto shift the
displayed function code from right to left.
3: Shift between forward rotations and
reverse rotations. Press QUICK/JOG to
shift the direction of the frequency
commands. This function is only valid in
the keypad commands channels.
4: Clear UP/DOWN settings. Press
QUICK/JOG to clear the set value of
1
www.barghmaher.ir