Goodrive35 inverters Basic operation instruction
175
Function
code
Name
Detailed instruction of parameters
Default
value
3:Reserved
P00.18
Function
restore parameter
0:No operation
1:Restore the default value
2:Cancel the fault record
0
P00.15
Motor parameter
autotuning
0:No operation
1:Rotation autotuning
2: Static autotuning 1(autotune totally)
3: Static autotuning 2(autotune part
parameters)
0
P02.00
Motor type 1
0:Asynchronous motor
1:Synchronous motor
1
P02.01
Rated power of
asynchronous motor 1
0.1~3000.0kW
Depend
on model
P02.02
Rated frequency of
asynchronous motor 1
0.01Hz~P00.03(the Max. frequency)
50.00Hz
P02.03
Rated speed of
asynchronous motor 1
1~36000rpm
Depend
on model
P02.04
Rated voltage of
asynchronous motor 1
0~1200V
Depend
on model
P02.05
Rated current of
asynchronous motor 1
0.8~6000.0A
Depend
on model
P02.15
Rated power of
synchronous motor 1
0.1~3000.0kW
Depend
on model
P02.16
Rated frequency of
synchronous motor 1
0.01Hz~P00.03(the Max. frequency)
50.00Hz
P02.17
Number of poles pairs for
synchronous motor 1
1~128
2
P02.18
Rated voltage of
synchronous motor 1
0~1200V
Depend
on model
P02.19
Rated current of
0.8~6000.0A
Depend
www.barghmaher.ir