Goodrive35 inverters Basic operation instruction
190
Function
code
Name
Detailed instruction of parameters
Default
value
torque
( the rated current of the motor)
P03.13
Torque reference
filter time
0.000~10.000s
0.100s
P03.14
Upper frequency of
forward rotation in
vector control
0:Keypad (P03.16 sets P03.14,P03.17 sets
P03.15)
1: AI1
2: AI2
3: AI3
4:Pulse frequency HDI setting upper-limit
frequency
5:Multi-step setting upper-limit frequency
6:MODBUS communication setting upper-limit
frequency
7:PROFIBUS/CANopen communication setting
upper-limit frequency
8:Ethernet communication setting upper-limit
frequency
9: Reserved
0
P03.15
Upper frequency of
reverse rotation in
vector control
0
P03.16
Keypad setting for
upper frequency of
forward rotation
0.00Hz~P00.03 (the Max. frequency)
50.00 Hz
P03.17
Keypad setting for
upper frequency of
reverse rotation
0.00 Hz~P00.03 (the Max. frequency)
50.00 Hz
P03.18
Upper
electromotion
torque
source
0:Keypad setting upper-limit frequency(P03.20
sets P03.18, P03.21 sets P03.19)
1: AI1
2: AI2
3: AI3
4: HDI
5:MODBUS communication
0
P03.19
Upper braking
torque
source
0
www.barghmaher.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive 35 Series and is the answer not in the manual?

INVT Goodrive 35 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive 35 Series
CategoryInverter
LanguageEnglish

Related product manuals