Goodrive35 inverters Basic operation instruction
200
Function
code
Name
Detailed instruction of parameters
Default
value
P01.24
Delay time of the stopping
speed
0.00~60.00s
0.00s
P05.01~P0
5.09
Digital input function
selection
1: Forward rotation operation
2: Reverse rotation operation
4: Forward rotation jogging
5: Reverse rotation jogging
6: Coast to stop
7: Fault reset
8: Operation pause
21:ACC/DEC time option 1
22:ACC/DEC time option 2
30:ACC/DEC prohibition
P08.06
Jogging frequency
0.00~P00.03(the Max. frequency)
5.00Hz
P08.07
Jogging ACC time
0.0~3600.0s
Depend
on model
P08.08
Jogging DEC time
0.0~3600.0s
Depend
on model
P08.00
ACC time 2
0.0~3600.0s
Depend
on model
P08.01
DEC time 2
0.0~3600.0s
Depend
on model
P08.02
ACC time 3
0.0~3600.0s
Depend
on model
P08.03
DEC time 3
0.0~3600.0s
Depend
on model
P08.04
ACC time 4
0.0~3600.0s
Depend
on model
P08.05
DEC time 4
0.0~3600.0s
Depend
on model
P08.28
Fault reset times
0~10
0
P08.29
Interval time of automatic
fault reset
0.1~3200.0s
1.0s