Goodrive35 inverters Basic operation instruction
200
Function
code
Name
Detailed instruction of parameters
Default
value
P01.24
Delay time of the stopping
speed
0.00~60.00s
0.00s
P05.01~P0
5.09
Digital input function
selection
1: Forward rotation operation
2: Reverse rotation operation
4: Forward rotation jogging
5: Reverse rotation jogging
6: Coast to stop
7: Fault reset
8: Operation pause
21:ACC/DEC time option 1
22:ACC/DEC time option 2
30:ACC/DEC prohibition
P08.06
Jogging frequency
0.00~P00.03(the Max. frequency)
5.00Hz
P08.07
Jogging ACC time
0.0~3600.0s
Depend
on model
P08.08
Jogging DEC time
0.0~3600.0s
Depend
on model
P08.00
ACC time 2
0.0~3600.0s
Depend
on model
P08.01
DEC time 2
0.0~3600.0s
Depend
on model
P08.02
ACC time 3
0.0~3600.0s
Depend
on model
P08.03
DEC time 3
0.0~3600.0s
Depend
on model
P08.04
ACC time 4
0.0~3600.0s
Depend
on model
P08.05
DEC time 4
0.0~3600.0s
Depend
on model
P08.28
Fault reset times
0~10
0
P08.29
Interval time of automatic
fault reset
0.1~3200.0s
1.0s
www.barghmaher.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive 35 Series and is the answer not in the manual?

INVT Goodrive 35 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive 35 Series
CategoryInverter
LanguageEnglish

Related product manuals