Goodrive35 inverters Basic operation instruction
212
S1
S2
S3
S4
S5
S6
S7
S8
HD1
P05.10
P05.01
P05.02
P05.03
P05.04
P05.05
P05.06
P05.07
P05.08
P05.09
T delay
T delay
T delay
T delay
T delay
T delay
T delay
T delay
T delay
P05.15
P05.17
P05.19
P05.21
P05.23
P05.25
P05.27
P05.29
P05.31
0
1
2
3
4
5
.
.
.
.
29
30
P05.11
(default value is 1)
(default value is 4)
(default value is 7)
(default value is 0)
(default value is 0)
(default value is 0)
(default value is 0)
(default value is 0)
(default value is 0)
P05.00
0
1
0
1
-1
0
1
-1
0
1
-1
0
1
-1
0
1
-1
0
1
-1
0
1
-1
0
1
-1
0
1
-1
P17.11
Switch input terminal
state
0 No function 1 Forward running
4 Forward jogging 5 Reverse jogging
8 Running pause 9 External fault input
12
Frequency increasing/decreasing setting
clear
13
Shifting between A frequency and B
frequency
16 Multi-stage speed terminal 1 17 Multi-stage speed terminal 2
20 Multi-stage speed pause 21 ACC/DEC time selection 1
2 Reverse running
6 Coast to stop
10 Frequency setting increasing (UP)
14
Shifting between the combination setting
and A frequency
18 Multi-stage speed terminal 3
22 ACC/DEC time selection 2
23 Simple PLC pause 25 PID control pause
28 Counter reset 29 Torque control disabling
26
Traverse pause (stop at the current
frequency)
30 ACC/DEC disabling
32 Length reset 33
Frequency increasing/decreasing setting
clear
34 DC braking
3 3-wire running control
7 Fault reset
11 Frequency setting decreasing (DOWN)
15
Shifting between the combination setting
and B frequency
19 Multi-stage speed terminal 4
23 Simple PLC stopping reset
27
Traverse reset (stop at the middle
frequency)
31 Counter trigging
35 Shift from motor 1 to motor 2
36 Shift the command to the keypad 37 Shift the command to the terminal 38 Shift the command to the communication
39 Pre-exciting command
40 Power consumption clear 41 Power consumption keeping 42~63 Reserved
P07.37
The current fault
switch input terminal
state
Fault?
S1 BIT0 S2 BIT1
S3 BIT2 S4 BIT3
S5 BIT4 S6 BIT5
S7 BIT6 S8 BIT7
HDI BIT8
P05.10 P17.11 P07.37 display
P05.00
0: HDI is high speed pulse input
1: HDI is switch input
Fault
Running
Switch function selection
T delay
T delay
T delay
T delay
T delay
T delay
T delay
T delay
T delay
P05.14
P05.16
P05.18
P05.20
P05.22
P05.24
P05.26
P05.28
P05.30
This parameter is used to set the function corresponds to the digital multi-function terminals.
Note: two different multi-function terminals can not be set as one function.
Set
value
Function
Instructions
0
No function
The inverter does not work even there is input signal.
It is necessary to set the terminal which can not be
used to non-function to avoid misacting.
1
Forward running(FWD)
The forward or reverse rotation of the inverter can be
controlled by the external terminals.
2
Reverse running(REV)
3
3-wire running control
The terminal can determine the running mode of the
inverter is 3-wire control mode. Refer to P05.13 for
detailed instruction of 3-wire control mode.
4
Forward jogging
See P08.06, P08.07 and P08.08 for jogging
frequency, jogging ACC/DEC time.
5
Reverse jogging
6
Coast to stop
The inverter closes off the output. The motor is not
controlled by the inverter during the stopping. This
method is usually to be used when the load inertia is
big and it has no requirement to the stopping time.
It has the same meaning with the coast to stop in
P01.08 and usually used in remote control.
www.barghmaher.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive 35 Series and is the answer not in the manual?

INVT Goodrive 35 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive 35 Series
CategoryInverter
LanguageEnglish

Related product manuals