Goodrive35 inverters Basic operation instruction
213
External fault reset. It has the same function with the
reset function of STOP/RST on the keypad. This
function can realize remote fault reset.
The inverter decelerates to stop. But all running
parameters are in the memory state. For example,
PLC parameters, traverse parameters and PID
parameters. After the signal disappears, the inverter
will come back to the state before stopping.
When the external fault signal is sent to the inverter,
the inverter will report the fault and stop.
This parameter is used to modify the increasing and
decreasing command during the external terminal
given frequency.
Frequency increasing/decreasing setting clear
terminal can cancel the assistant channel frequency
set by the internal UP/DOWN of the inverter to make
the given frequency restore to the frequency given by
the main given frequency channel.
Frequency setting
down(DOWN)
Frequency
increasing/decreasing setting
clear
Switch between A setting and
B setting
This function can realize the shifting between the
frequency setting channels.
The 13
th
function can realize the shifting between A
frequency given channel and B frequency given
channel.
The 14
th
function can realize the shifting between A
frequency given channel and the combination setting
channel set by P00.09
Switch between A setting and
combination setting
Switch between B setting and
combination setting