Goodrive35 inverters Fault tracking
252
The actual running time of
the inverter is above the
internal setting running time.
Ask for the supplier and adjust
the setting running time.
Keypad
communicatio
n fault
The connection of the
keypad wires is not good or
broken.
The keypad wire is too long
and affected by strong
interference.
There is circuit fault on the
communication of the
keypad and main board.
Check the keypad wires and
ensure whether there is mistake.
Check the environment and
avoid the interference source.
Change the hardware and ask
for service.
Parameters
uploading
fault
The connection of the
keypad wires is not good or
broken.
The keypad wire is too long
and affected by strong
interference.
Communication fault.
Check the keypad wires and
ensure whether there is mistake.
Change the hardware and ask
for service.
Change the hardware and ask
for service.
Parameters
downloading
fault
The connection of the
keypad wires is not good or
broken.
The keypad wire is too long
and affected by strong
interference.
There is mistake on the data
storage of the keypad.
Check the keypad wires and
ensure whether there is mistake.
Change the hardware and ask
for service.
Repack-up the data in the
keypad.
Electronic
underload
fault
The inverter will report the
underload pre-alarm
according to the set value.
Check the load and the
underload pre-alarm point.