Goodrive35 inverters Communication protocol
278
Function
instruction
Address
definition
Data meaning instruction
R/W
characteristics
0004H:reverse jogging
0005H:stop
0006H:coast to stop (emergency stop)
0007H:fault reset
0008H:jogging stop
The address of
the
communication n
setting value
2001H
Communication setting
frequency(0~Fmax(unit: 0.01Hz))
W/R
2002H
PID given, range(0~1000, 1000 corresponds
to100.0% )
2003H
PID feedback, range(0~1000, 1000
corresponds to100.0% )
W/R
2004H
Torque setting value (-3000~3000, 1000
corresponds to the 100.0% of the rated current
of the motor)
W/R
2005H
The upper limit frequency setting during
forward rotation(0~Fmax(unit: 0.01Hz))
W/R
2006H
The upper limit frequency setting during
reverse rotation(0~Fmax(unit: 0.01Hz))
W/R
2007H
The upper limit torque of electromotion torque
(0~3000, 1000 corresponds to the 100.0% of
the rated current of the motor)
W/R
2008H
The upper limit torque of braking torque
(0~3000, 1000 corresponds to the 100.0% of
the rated current of the motor)
W/R
2009H
Special control command word
Bit0~1:=00: motor 1 =01: motor 2
=10: motor 3 =11: motor 4
Bit2:=1 torque control =0:speed control
Bit3:=1 power consumption clear
=0:no power consumption clear
Bit4:=1 pre-exciting enabling
W/R
www.barghmaher.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive 35 Series and is the answer not in the manual?

INVT Goodrive 35 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive 35 Series
CategoryInverter
LanguageEnglish

Related product manuals