Goodrive35 inverters Appendix A
303
Request label (From master to slave)
Response label
3
Modification parameter value (double word)
[only change RAM]
2
3 or 4
4
Modification parameter value (one word)
[RAM and EEPROM are modified]
1
3 or 4
5
Modification parameter value (double word)
[RAM and EEPROM are modified]
2
3 or 4
Request label
"2"-modification parameter value (one word) [only change RAM],
"3"-modification parameter value (double word) [only change RAM]
"5"-modification parameter value (double word) [RAM and EPROM are modified] not support
currently.
Reponses logo PKW1 defines as below:
Response label (From slave to master)
Confirmation
Function
0
No response
1
Transmission parameter value ( one word)
2
Transmission parameter value ( two words)
3
Task can not be executed and returns the following error number:
0: Illegal parameter number
1: Parameter values can not be changed (read-only parameter)
2: Out of set value range
3: The sub-index number is not correct
4: Setting is not allowed (only reset)
5: Data type is invalid
6: The task could not be implemented due to operational state
7: Request isn’t supported.
8: Request can’t be completed due to communication error
9: Fault occurs when write operation to stationary store
10: Request fails due to timeout
11: Parameter can not be assigned to PZD
12: Control word bit can’t be allocated
13: Other errors
www.barghmaher.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive 35 Series and is the answer not in the manual?

INVT Goodrive 35 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive 35 Series
CategoryInverter
LanguageEnglish

Related product manuals