Goodrive35 inverters Function codes
69
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
off
Setting range: 0.0~3600.0s (valid when P01.21=1)
P01.23
Start delay
time
The function determines the brake release after the
running command is given, and the inverter is in a
stand-by state and wait for the delay time set by
P01.23
Setting range: 0.00~60.00s
0.00s
P01.24
Delay time
of the stop
speed
Setting range: 0.0~60.0s
0.0s
P01.25
DEC time
of E-stop
DEC time of E-stop.
Setting range: 0.00~60.00s
2.00s
P02 Group Motor 1
P02.00
Motor type
1
0:Asynchronous motor
1:Synchronous motor
Note: Switch the current motor by the switching
channel of P08.31.
0
P02.01
Rated
power of
asynchron
ous motor
1
0.1~3000.0kW
Depend
on
model
P02.02
Rated
frequency
of
asynchron
ous motor
1
0.01Hz~P00.03(the Max. frequency)
50.00
Hz
P02.03
Rated
1~36000rpm
Depend