Goodrive35 inverters Function codes
92
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
terminal is valid, the inverter stop because of the
stopping command from other sources, even the
control terminal FWD/REV keeps valid; the inverter
wont work when the stopping command is
canceled. Only when FWD/REV is relaunched, the
inverter can start again. For example, the valid
STOP/RST stop when PLC signal cycles stop,
fixed-length stop and terminal control (see P07.04).
P05.14
Switch-on
delay of S1
terminal
The function code defines the corresponding delay
time of electrical level of the programmable terminals
from switching on to switching off.
Note: P05.30 and P05.31 are valid when P05.00=1.
Setting range:0.000~50.000s
0.000s
P05.15
Switch-off
delay of S1
terminal
0.000s
P05.16
Switch-on
delay of S2
terminal
0.000s
P05.17
Switch-off
delay of S2
terminal
0.000s
P05.18
Switch-on
delay of S3
terminal
0.000s
P05.19
Switch-off
delay of S3
terminal
0.000s
P05.20
Switch-on
delay of S4
terminal
0.000s
P05.21
Switch-off
delay of S4
terminal
0.000s