Goodrive35 inverters Function codes
91
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
COM
K
SB2
SB1
FWD
REV
SIn
The direction control is as below during operation:
Sln
REV
Previous
direction
Current
direction
ON
OFF→ON
Forward
Reverse
Reverse
Forward
ON
ON→OFF
Reverse
Forward
Forward
Reverse
ON→OF
F
ON
Decelerate to stop
OFF
3:3-wire control 2; Sin is the enabling terminal on this
mode, and the running command is caused by SB1
or SB3 and both of them control the running
direction.NC SB2 generates the stop command.
COM
SB2
SB1
FWD
REV
SIn
SB3
Sln
FWD
REV
Direction
ON
OFF→O
N
ON
Forward
OFF
Reverse
ON
ON
OFF→O
N
Forward
OFF
Reverse
ON→OF
F
Decelerat
e to stop
Note: for the 2-wire running mode, when FWD/REV