EasyManua.ls Logo

INVT Goodrive 35 Series - Page 91

INVT Goodrive 35 Series
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive35 inverters Function codes
90
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
BIT7:S8 virtual terminal
BIT8:HDI virtual terminal
P05.13
Terminals
control
running
mode
Set the operation mode of the terminals control
0:2-wire control 1, comply the enable with the
direction. This mode is widely used. It determines
the rotation direction by the defined FWD and REV
terminals command.
1:2-wire control 2; Separate the enable from the
direction. FWD defined by this mode is the enabling
ones. The direction depends on the state of the
defined REV.
2:3-wire control 1; Sin is the enabling terminal on this
mode, and the running command is caused by FWD
and the direction is controlled by REV. Sin is
natural closed.
0