Ref.: IR14417 A 15.01.2018 Page 21/76
green LED, left
RJ45
Jack
yellow LED, right
link active
speed
3.1.3.9 INTERNAL INTERFACES
For software development and test purposes only there are interfaces on the board, which
are accessible only with opened case:
- JTAG-interface to XC167-processor
- JTAG-interface to AT91- processor
- RS232-interface to AT91- processor
- USB-interface to AT91- processor
These interfaces are of no concern for the user and must not be operated for any purpose.
3.1.3.10 LEDS
There are 5 + 2 LEDs at the front side right of the RS232-jack with software dependent
meanings.
3.1.4. ELECTROMECHANICS
The supply- and the I/O-interfaces are realized with the MCP 2.8 mm interconnection
system by TYCO-AMP. The tab housing cavities mate with Junior Power Timer crimp
contacts without single wire seal with maximum wire size of 2.5 mm².
TYCO-AMP order for the connector:
- TYCO Fem-Cable-Connector 21POL: 1-967625-2
- TYCO Fem-Cable-Connector 6POL: 1-965640-3
- TYCO Fem-Cable-Connector 9POL: 1-967621-4
TYCO-AMP order numbers for JPT-contacts spare parts
(loose piece, ‘x’ and ‘y’ depend on material and finish):
- 1.0…2.5 mm² x-927777-y
- 0.5…1.0 mm² x-927779-y
- 0.2…0.5 mm² x-927776-y
- extraction tool 1-1579007-6
ATTENTION:
The tab housings are not coded. Take care to avoid misconnections of tab housings
with same pin count.