EasyManua.ls Logo

I+ME ACTIA BMS Master 4 - Environmentals

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Manual
BMS Master 4 / 4.5
Ref.: IR14417 A 15.01.2018 Page 52/76
Peak consumption while communicating with MASTER ~ 20 mA
Stand-by/sleep-mode with MASTER inactive ≤ 0.03 mA
Balancing current per cell without external resistors (voltage dependent) 70 ... 90 mA
3.5.9. ENVIRONMENTALS
Humidity: max 95%, non-condensing
Working temperature: -20°C ... +70°C
Storage temperature: -40°C ... +70°C
At pollution level 2 the Slave may be operated at voltages up to 650 VDC
At pollution level 3 the Slave must not be operated
In applications with voltage differences > 650 VDC non-conducting screws (e.g. Nylon)
have to use for fixing the molded module.
Maximum insulation voltage must not exceed 1000 VDC.
Environmental testing:
Temperature Test acc. ISO16750-4:
o 24 h at 40 °C
o 96 h at +85 °C
o 4 x Cycles at -40°C and +85°C
Insulationtest: 300GΩ / 5kV DC.
EMC: according EN 55022 and EN 55024 (industrial)

Table of Contents