Command Reference Epic 950 OEM Integration Manual
Page 112 Rev G 95-05245
GS ! Select Character Size
Description
This command selects the character height using bits 0 to 2 of parameter n, and selects
the character width using bits 4 to 7 of this parameter, as shown below.
Expression
ASCII [GS] ! <n>
Hexadecimal 1DH 21H <n>
Decimal <29><33><n>
Parameters n = parameter ranging from 0-255
Height (bits 0-2) and width (bits 4-7) values
range from 1-8, per table below.
Character height selection
Hex Decimal Height
00 0 1 (normal)
01 1 2 (double-high)
02 2 3
03 3 4
04 4 5
05 5 6
06 6 7
07 7 8
Character width selection
Hex Decimal Width
00 0 1 (normal)
10 16 2 (double-wide)
20 32 3
30 48 4
40 64 5
50 80 6
60 96 7
70 112 8