Command Reference Epic 950 OEM Integration Manual
Page 130 Rev G 95-05245
GS h Set Bar Code Height
Description
Defines the height of the bars (in dots) for bar codes. The height is defined in n/203 inch
increments, corresponding to the height of a single dot. For example, specify 203 as the
value for n to print a 1-inch high bar code. Note that the bar code height is always
rounded up to the next multiple of 8.
The default setting is 100.
Expression
ASCII [GS] h <n>
Hexadecimal 1DH 68H <n>
Decimal <29> <104> <n>
Parameters n = the desired height (in dot lines) of the bar code,
where n/203 represents the height in inches.