EasyManua.ls Logo

JRC NCR-333 - 7.2.1 Confirming the RX station and Message type

JRC NCR-333
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I 6.3.3.1 Contrast adjustment (CONTRAST)
1.
CONTRAS When is selected, CONTRAST is ready to be entered.
To
adjust the contrast, press the
~
~
key, and then press the
IEN1j
key.
I
'
''
'
''
'
'''''''''''''''''
(Q
''
' ' I
1.CONTRAST
: t
'''''''''''
'
''
'
''
'
''''
' '
''''
The adjustment
of
the contrast
-
M1"
is the darkest.
-
M13•
is the lightest.
The initial setting is "7·.
I 6.3.3.2 Back
light
settings (DIMMER)
Brightness can be changed into four levels (MAXIMUM, TYPICAL, MINIMUM and OFF)
by
pressing the
IDIMI
key. These brightness levels are set up in this item.
The increase
value
of
the brightness
at
the time
of
alarm generating can be changed from
+1
to +9.
Select
~.J•MIM#].
and press the
IEN1j
key. Cursor moves to the right side
of
":R.
Number and brightness is changed when
the~~
key is pressed, and then press the
IEN1j
key.
Press the
IEN1j
key after setting up to "ALERT". All setting values are saved.
·'''''''''''''''
'
''
'
''
'
'''''
'
''
'
''
' ' . ' ' . ' ' . ' ' . . ' ' . ' ' . ' . . ' . . ' . . ' '
..
'
2.DIMMER
MAXIMUM
TYPICAL
MINIMUM
ALERT
m
8
4
+2
tr==="'
'•
'·
'·
'·
'·
'·
'·
'·
'·
'·
'· '
I(
Notes
Jl
MMAXIMUM"
should enter the largest numerical value and "MINIMUM" should enter the smallest
numerical value.
When not connect to the BAM, "ALERT' is displayed instead
of
MALARM·.
I 6.3.3.3 Buzzer settings (BUZZER)
When - is selected, each buzzer functions can be set enable (ON)
or
disable (OFF) as followings.
Press the
..-key
and select the "ON"
or
"OFF".
Press the EN key after setting up to "CLICK''. All buzzer settings are saved.
''''
'
''
'
''
'
''
'
''
'
''
'
''
' '
~
'
'
''
'
''
3.
BUZZER
:
~
ALERT
MSG
:
OFF
(FOR
MESSAGE
TYPE:A,B,L)
RECEIVED
MSG
ON
BAM
ALERT
:
OFF
CLICK
:
ON
ON:
OFF:
A buzzer is sounded.
A buzzer is not sounded.
,,,,,,,,,,,,,
,
,,
,
,,
,
,,
,
,,
,
,,
,
,,
,,
OFF: All buzzer functions are disabled. BUZZER:
-ALERT
MSG:
ON:
Each buzzer function as shown below can be enabled.
When a message (A,
Band
L) is received.
-RECEIVED
MSG:
-BAM
ALERT
-CLICK:
I(
Caution
Jl
When a message (other than A,
Band
L) is received.
When a
failure alarm occurs.
When a key is pressed.
When search and rescue message (D) is received, buzzer sounds. The
SAR buzzer sound can not be
set
to
"OFF (disable)".
6-39

Table of Contents

Other manuals for JRC NCR-333

Related product manuals