7. 
2  Periodic 
Ins 
ection 
Regarding the functions for performing self-diagnosis and monitoring the system status,  please 
refer 
to 
"6.3.5 MAINTENANCE menu(MAINTENANCE)" 
I 
7.2.1 
Confirming the 
RX 
station 
and 
Message 
type 
To 
check the receiving station and message type, please refer 
to 
6.1.3 and 6.3.2. Be sure to set 
up the receiving station and message type 
correctly. 
I 7 .2.2 Confirming the Alert I 
Alarm 
Status 
(A) When connected to the BAM 
With referring 6.3.5.2(A), confirm that 
failure alert 
is 
not occurring. 
If 
any 
alert occurs, check the 
cause 
of 
the alert. NCR-333 Alert Table is followings. 
NCR-333 Alert Table 
Failure alert list  (ALF sentence output) 
Alert ID  Indication 
Alarm 
Occurrence Conditions 
3079,1  Built in 
self 
test failure  After carrying  out self-diagnosis,  NCR-333 detected 
3079,2  General failure 
that the input voltage was abnormal. 
3079,1  Built 
in 
self 
test failure 
After carrying  out self-diagnosis,  NCR-333 detected 
3079,3  Antenna inoperative 
that the  output 
voltage 
of 
antenna terminal was  low 
voltage. 
3079,1  Built 
in 
self 
test failure 
After carrying  out self-diagnosis,  NCR-333 detected 
3116,1  518kHz inoperative 
that  the  receiver  1  (518kHz) 
could  not  receive 
because of 
abnormalities. 
3079,1  Built 
in 
self 
test failure 
After carrying  out self-diagnosis,  NCR-333 detected 
3116,2 
490kHz inoperative 
that  the  receiver  2 
(490kHz)  could  not  receive 
because of 
abnormalities. 
3079,1 
Built 
in 
self 
test failure  After carrying  out self-diagnosis,  NCR-333 detected 
3116,3  4.2MHz inoperative 
that  the  receiver  3  (4209.5kHz) 
could  not  receive 
because of 
abnormalities. 
3079,2  General failure 
The input voltage is low level. 
3079,5 
Rx 
unit modem error 
The receiver 1 (518kHz) 
could  not receive  because 
3116,1  518kHz inoperative 
of 
internal MODEM failure. 
3079,5 
Rx 
unit modem error  The receiver 2  (490kHz) could  not receive  because 
3116,2 
490kHz inoperative 
of 
internal MODEM failure. 
3079,5 
Rx 
unit modem error 
The  receiver  3 
(4209.5kHz)  could  not  receive 
3116,2  4.2MHz inoperative 
because of 
internal MODEM failure. 
3079,3 
Antenna inoperative 
The  output 
voltage  of  antenna  terminal  is  low 
voltage. 
3079,4 
Flash 
memory error  The flash memory data 
is 
abnormal. 
3079,6  Printer 
error 
External printer 
is 
abnormal. 
7-2