FX-1/FX-1R Maintenance Manual
2-9. List of Readjustment Items After Replacement
Laser offset Head offset
Mounting
general offset
Head unit assembly { { {
Z-motor {

θ-motor
{

Z-sensor {

Laser sensor { { {
Head-up SP

Timing belt Z {

Timing belt θ
{

S housing assembly { { {
Nozzle outer shaft { { {
The MS parameters must be input from the left in order.
When inputting the laser offset after the head unit, Z-motor, or timing belt-Z has been replaced, input
the laser offset after the top surface height of the laser offset board has been adjusted to “0”. The
offset cannot be obtained correctly or cannot be obtained automatically depending on the offset
value, which has been set before replacement.
CAUTION
To prevent personal injury, do not put your hand inside the machine
or your face or head close to the machine during operation of the
HOD.