EasyManuals Logo

JUKI FX-1R User Manual

JUKI FX-1R
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
FX-1/FX-1R Maintenance Manual
8-4. Replacing the Feeder Bank Board and Feeder I/F Board
(1) Disconnect the feeder bank relay cable and air coupler nipple from the main unit.
(2) Remove the mounting screws to detach the connector bracket.
(3) Disconnect the connectors from the feeder bank board and feeder I/F board.
(4) To detach the feeder board, remove eight screws. To detach the feeder I/F board, remove four
nuts. After relevant board has been detached, replace it with a new one.
(5) Reassemble the components in the reverse order of disassembly.
Feeder board
A
ir coupler nipple
Feeder I/F board
Rela
y
cable
Figure 8-4-1
8-5
Rev. 2.00