FX-1/FX-1R Maintenance Manual
DANGER
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
[3] PARTS AROUND THE HEAD
3-1. Replacing the Ejector Unit
Before replacing the ejector unit, always shut-down the main compressed air.
Since the solenoid valve is a type of connector connection, carefully connect them to avoid improper
connections. After the ejector unit has been replaced, turn on and off the manual control head
vacuum blow to check that the ejector unit functions correctly.
(Note) Carefully disassemble the unit so that oil seals on the rear of the solenoid valve
and O-ring of the pressure sensor are not lost.
Solenoid valve for vacuum
production
Round head screw (
× 2)
Gasket
Solenoid valve for vacuum
vent
Round head screw (
× 2)
Gasket
Vacuum senso
Round head screw (
× 2)
O-ring
Silencer cover
Round head screw (
× 1)
Round head screw
2
Vacuum sensor Solenoid valve
Silencer
Replacing the silencer Ejector main unit (Left: front view/right: side view)
Figure 3-1-1 Replacing the Ejector
3-1
Rev. 2.00