Table 21: AC Power Cord Specifications
GraphicJuniper Model NumberPlug StandardsElectrical SpecificationsCountry/Region
CBL-GP-PWR-C13-AUAS/NZ 3109-1996250 VAC, 10 A, 50 HzAustralia
CBL-GP-PWR-C13-CHGB 1002-1996250 VAC, 10 A, 50 HzChina
CBL-GP-PWR-C13-EUCEE (7) VII250 VAC, 10 A, 50 HzEurope (except Italy,
Switzerland, and
United Kingdom)
CBL-GP-PWR-C13-ITCEI 23-16/VII250 VAC, 10 A, 50 HzItaly
CBL-GP-PWR-C13-JPJIS C8303125 VAC, 12 A, 50 Hz or
60 Hz
Japan
g021274
CBL-GP-PWR-C13-USCAN/CSA No. 49-92125 VAC, 13 A, 60 HzNorth America
CBL-GP-PWR-C13-KRKSC 8305; K60884-1250 VAC, 10 A, 60 HzSouth Korea
CBL-GP-PWR-C13-SZSEV 1011 SEV 1991;
EN 60320 C13
250 VAC, 10 A, 50 HzSwitzerland
CBL-GP-PWR-C13-UKBS 1363/A250 VAC, 10 A, 50 HzUnited Kingdom