3. Turn the chassis right side up on the desk or the level surface.
4. If it is an EX4200-24F switch, we recommend you insert dust covers in unused SFP
ports.
Figure 30: Attaching Rubber Feet to an EX4200 Switch Chassis
Related
Documentation
Connecting AC Power to an EX4200 Switch on page 149•
• Connecting DC Power to an EX4200 Switch on page 152
• Connecting and Configuring an EX Series Switch (CLI Procedure) on page 165
• Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 168
• Clearance Requirements for Airflow and Hardware Maintenance for EX4200 Switches
on page 70
Mounting an EX4200 Switch on Two Posts in a Rack or Cabinet
You can mount an EX4200 switch on two posts of a 19-in. rack (either a two-post or a
four-post rack) or a 19-in. cabinet by using the mounting brackets provided with the
switch. (The remainder of this topic uses “rack” to mean “rack or cabinet.”)
You can mount the switch on four posts of a four-post rack by using the mounting brackets
provided with the separately orderable four-post rack-mount kit. See “Mounting an
EX4200 Switch on Four Posts in a Rack or Cabinet” on page 133.
NOTE: If you need to mount the switch in a recessed position on either a
two-post rack or a four-post rack, you can use the 2-in.-recess front brackets
provided in the separately orderable four-post rack-mount kit.
Before mounting the switch on two posts in a rack: