EasyManuals Logo

KEB COMBIVERT F4-F Applications Manual

KEB COMBIVERT F4-F
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
28
6
Name: Basis
KEB COMBIVERT F4-F
17.09.98
Functional Description Analog In- and Outputs
Chapter
Section
Page
Date
© KEB Antriebstechnik, 1998
All Rights reserved
+100%
+100%
-100%
-100%
An.3
+100%
+100%
-100%
-100%
An.4
+75%
1.
2.
An.3 = +1, An.4 = 0%, An.5 = 0%
An.3 = -1, An.4 = 0%, An.5 = 0%
An.3 = -1, An.4 = 0%, An.5 = 0%
An.3 = -1, An.4 = +75%, An.5 = 0%
+100%
+100%
-100%
-100%
An.5
+100%
3.
An.3 = -1, An.4 = +75%, An.5 = 0%
An.3 = -1, An.4 = +75%, An.5 = +100%
Fig. 6.2.7 Gain (An.3)= -1, X-Offset (An.4)= +75%, Y-Offset (An.5)= +100%
Example 2: Following values shall be adjusted for the input REF1 ± :
1. Gain adjusted to -1 (single amplification)
2. X-Offset adjusted to 75 %
3. Y-Offset adjusted to 100 %
With these settings and inverted setpoint setting in the range of +75...+100 % IN by
way of input REF1 ± a speed range of +100...+75% OUT can be driven, that means:
0% IN correspond to +100% OUT
+75% IN correspond to +100% OUT
+100% IN correspond to +75% OUT
To avoid the wrong programming of the analog input signals the IN / OUT adaption
should be checked by way of control diagrams (see above).

Table of Contents

Other manuals for KEB COMBIVERT F4-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-F and is the answer not in the manual?

KEB COMBIVERT F4-F Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-F
CategoryLifting Systems
LanguageEnglish