EasyManua.ls Logo

KEB COMBIVERT F4-F - Operation; Digital-; Interface-Operator

KEB COMBIVERT F4-F
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ANTRIEBSTECHNIK
2
© KEB Antriebstechnik, 1998
All Rights reserved
Chapter
Section
Page
Date
2
15
KEB COMBIVERT F4-F
Name: Basis
11.12.98
Product Description Summary
2.1.4 Type Code
Options 0 = Standard
Clock frequency 4 = 8 kHz
8 = 16 kHz
Supply voltage 2 = 230 V-Class
4 = 400 V-Class
Input code 1 = 1-phase
2=DC
3 = 3-phase
4 = Special- / customer version *
5 = Special- / customer version *
Housing design D, E, G, H, K, L, M, N, P, R
Accessories 0 = None
1 = Braking transistor
2 = Filter
3 = Filter and braking transistor
Used control F = Field-oriented control
Series F4
Housing size 07...29
Part Number
*) For customer or special versions the last 4 digits are different from the above type code.
15.F4.F1G–3440

Table of Contents

Other manuals for KEB COMBIVERT F4-F