ANTRIEBSTECHNIK
2
© KEB Antriebstechnik, 1998
All Rights reserved
Chapter
Section
Page
Date
2
17
KEB COMBIVERT F4-F
Name: Basis
11.12.98
Product Description Summary
2.1.7 Unit Sizes 400V-Class
1) From housing size M fuses of Type Ferra Z 6,6 URD xxx must be used.
2) This data is only valid for units with internal brake transistor (see „2.1.4 Type Code“).
3) At mains voltage ≥460V multiply the nominal current with factor 0,86.
4) These units can be used with one or more braking modules. For more informations cantact KEB.
Inverter Size 10 12 13 14 15 16 17
Output nominal power [kVA 4 6,6
8,3 11 17 23 29
Max. rated motor power [kW] 2,2 4
5,5 7,5 11 15 18,5
Output nominal current [A] 5,8 9,5
12 16,5 24 33 42
Max. short-time current [A] 10,4 17,1 21,6 18 29,7 24,8
36 49,5 63
OC-tripping current [A] 12,7 20,9 26,4 21,6 36,3 29,7
43,2 59,4 75,6
Nominal input curren [A] 6,4 10,5
13,2 18,1 26,5 36,5 46
Housing size D E E G E G G H G H H R
Rated operating frequency [kHz] 8 16
16 8 16 8 16 8 16 8 16
Max.operating frequency [kHz] 16 16
16 16 16 16 16 16 16 16 16
Power loss at nominal operating [W] 130 180 240 200 240 260 290 360 310 490 470 700
Stall current at 8kHz [A] 6,4 9,5 12 19 16,5 19 19 25 21,5 33 30 42
Stall current at 16kHz [A] - 9,5 12 12 - 12 8,5 15 9,7 20 13,5 30
Max. heat sink temperatureT
OH
[°C] 79 73 73 90 73 90 90 90 90 79
Max. permissible mains fuse (inert)
1)
[A] 10 20 20 25 35 50 63
Line cross section [mm²]1,5 2,5
2,5 4 6 10 16
Min. braking resistor
2)
[
Ω
] 160 50 50 39 50 39 22 25 22 22 9
Typ. braking resistor
2)
[
Ω
] 270 150 100 82 56 39 28
Max. braking current [A] 5 15 15 21 15 21 21 37 30 37 37 88
Tightening torque for terminals [Nm] 0,5 0,5 0,5 1,2 0,5 1,2 1,2 2,5 1,2 2,5
2,5
Mains voltage
3)
[V]
305...500 +/-0 (400V Nominal voltage)
1)
Phases 3
Mains frequency [Hz]
50 / 60 +/- 2
Output voltage [V]
3 x 0...U Mains
Output frequency [Hz]
see control board
Shielded motor line length [m]
100
Storage temperature [°C]
-25...70 °
Operating temperature [°C]
-10...45 °
Model / protective system
IP20
Relative humidity
max. 95% without condensation
Tested in accordance with...
EN 61800-3
Climatic category
3K3 in accordance with EN 50178
(10-17)