Parameter
51
KEB COMBIVERT F4-C
6
Name: Basis
Chapter
Section Page Date
© KEB Antriebstechnik, 1999
All Rights reserved
21.06.99
Pn 16 E.dOH delay time 2210 - - 0 120 1 0 sec 6.3.10, 6.6.3, 6.6.4
Pn 17 power off start voltage 2211 - ✓✓ 198 800 1 198 –– 6.8.13
Pn 20 extern fault stopping condition 2214 - ✓✓ 061 0–– 6.6.4
Pn 23 E.bus stopping condition 2217 - ✓✓ 061 6–– 11.2.3
Pn 24 prohibited rotation stopping condition 2218 - ✓✓ 061 6–– 6.11.7
Pn 25 warning dOH stopping condition 2219 - ✓✓ 061 6–– 6.6.3
Pn 26 warning OH stopping condition 221A - ✓✓ 061 6–– 6.6.3
Pn 33 power off mode 2221 - ✓✓ 121 2–– 6.8.13
Pn 60 torque for abnormal stop 223C - ✓✓ 0,0 5 x dr.09 0,1 ? Nm 6.8.13
dr - Parameter Addr.
min
max
default
[?] see Page(s)
dr 0 rated motor power 2400 - ✓✓ 0 ,01 75 0,01 *) kW 6.5.3
dr 1 rated motor speed 2401 - ✓✓ 100 9999 1 *) rpm 6.5.3
dr 2 rated motor current 2402 - ✓✓ 0,1 1,1 x In.1 0,1 *) A 6.5.3
dr 3 rated motor frequency 2403 - ✓✓ 20 300 1 50 Hz 6.5.3, 6.5.5
dr 4 rated motor cos (phi) 2404 - ✓✓ 0,05 1,00 0,01 *) –– 6.5.3
dr 9 rated motor torque 2409 - - - 0,1 1000,0 0,1 –– Nm 6.5.11
dr 10 maximum torque 240A - - - 0,1 1000,0 0,1 –– Nm 6.5.5, 6.5.11
dr 12 rated motor voltage 240C - ✓✓ 100 500 1 400 V 6.5.3, 6.5.5
dr 13 speed for maximum torque 240D - ✓✓ 0,0 9999,5 0,5 1000,0 rpm 6.5.5, 6.5.11
dr 16 maximum torque corner speed 2410 - ✓✓ 0,0 5 x dr.09 0,1 1,5 x dr.09 *) Nm 6.5.5, 6.5.11
dr 19 corner speed field weakening 2413 - ✓✓ 200,0 9999,5 0,5 1300,0 rpm 6.5.6, 6.5.12
dr 20 field weakening curve 2414 - ✓✓ 0,10 2,00 0,01 1,20 –– 6.5.12
dr 21 flux adaption factor 2415 - ✓✓ 25 250 1 100 % 6.5.12
dr 25 encoder 1 (inc/r) 2419 - ✓✓ 256 10000 1 2500 inc/r 6.9.8
dr 28 encoder 1 counter mode 241C - ✓✓ 011 0–– 6.9.8
dr 29 change encoder 1 rotation 241D - ✓✓ 011 0–– 6.9.8
dr 30 encoder 2 (inc/r) 241E - ✓✓ 256 10000 1 2500 inc/r 6.9.8
dr 31 multiturn resolution encoder 2 241F - - 0131 0–– 6.9.7
dr 32 encoder 2 clock frequency 2420 - - 011 0–– 6.9.7
dr 32 encoder 2 code 2421 - - 011 0–– 6.9.7
dr 34 change encoder 2 rotation 2422 - ✓✓ 011 0–– 6.9.8
dr 39 encoder 2 mode 2427 - ✓✓ 011 1–– 6.9.6
dr 40 time for speed calculation 2428 - ✓✓ 051 3–– 6.9.8
dr 50 stator resistance 2432 - ✓✓ 0,000 32,767 0,001 1,100 Ohm 6.5.13
dr 51 leakage reactance 2433 - ✓✓ 0,00 327,67 0,01 10,58 mH 6.5.13
dr 52 motor connection 2434 - ✓✓ 011 1–– 6.5.13
CS - Parameter Addr.
min
max
default
[?] see Page(s)
CS 0 KP speed 2D00 - 0 32767 1 400 –– 6.5.10
CS 1 KI speed 2D01 - 0 32767 1 200 –– 6.5.10
CS 3 KP speed gain 2D03 - - 0 32767 1 0 –– 6.5.10
CS 4 KP speed limit 2D04 - - 0 32767 1 0 –– 6.5.10
CS 6 torque limit forward positive 2D06 - 0,0 5 x dr.9 0,1 dr.10 Nm 6.5.11
CS 7 torque limit reverse positive 2D07 - -0,1 : off 5 x dr.9 0,1 -0,1 : off Nm 6.5.11
CS 8 torque limit forward negative 2D08 - -0,1 : off 5 x dr.9 0,1 -0,1 : off Nm 6.5.11
CS 9 torque limit reverse negative 2D09 - -0,1 : off 5 x dr.9 0,1 -0,1 : off Nm 6.5.11
CS 10 aktivation of adaptation 2D0A - - 0 65535 1 0 –– 6.5.13
CS 11 KI offset 2D0B - - 0 65535 1 0 –– 6.5.10
CS 12 max speed for max Ki 2D0C - - 0,0 9999,5 0,5 10,0 rpm 6.5.10
CS 13 min. speed for Cs.01 2D0D - - 0,0 9999,5 0,5 500,0 rpm 6.5.10
CS 14 standstill position control 2D0E - - 0 65535 1 0 –– 6.5.10
CS 19 KP flux 2D13 - - 0 : off 65535 1 0 : off –– 6.5.12
CS 20 KI flux 2D14 - - 1 65535 1 1 –– 6.5.12
CS 21 magn. current limit 2D15 - - 0,0 In.1 0,1 0,0 A 6.5.12
CS 22 flux mode 2D16 - ✓✓ 011 0–– 6.5.13
CS 23 speed regulation active 2D17 ✓✓ 0 : off 1 1 0 : off –– 6.5.5
ds - Parameter Addr.
min
max
default
[?] see Page(s)
ds 0 KP I active 2F00 - - 1 65535 1 1500 –– 6.5.9
ds 1 KI I active 2F01 - - 1 65535 1 500 –– 6.5.9
ds 5 KP I magnetizing 2F05 - - 0 65535 1 -1 : off –– 6.5.9
ds 6 KI I magnetizing 2F06 - - 0 65535 1 -1 : off –– 6.5.9
ds 9 no load voltage 2F09 - - 0,0 100,0 0,1 75,0 % 6.5.9
ds 10 DC voltage compensation 2F0A - ✓✓ 180 500 1 501 : off V 6.5.6
ds 11 boost 2F0B - - 0,0 25,5 0,1 2,0 % 6.5.6
ds 12 modulation depth 2F0C - - - 0 100 1 % 6.5.8
ds 13 carrier frequency 2F0D - ✓✓ 011 0–– 6.5.8
ds 14 overmodulation 2F0E - ✓✓ 011 1–– 6.5.8
dS 15 Adaption factor 2F0F - - - 0,0 : off 100,0 0,1 - % 6.5.14
ud - Parameter Addr.
min
max
default
[?] see Page(s)
ud 0 key password input 2600 - ✓✓ 0 9999 1 cp_on –– 4.4.3
ud 1 bus password input 2601 - - -32767 32767 1 cp_on –– 6.12.5
ud 2 start parameter group 2602 - - 1 : ru 16 : Pd 1 1 : ru –– 6.12.4
ud 3 start parameter number 2603 - - 0 255 1 1 –– 6.12.4
ud 6 inverter address 2606 - ✓✓ 0 239 1 1 –– 11.2.3
ud 7 baud rate 2607 - ✓✓ 1200 57600 table 9600 Baud 11.2.3