Condition-
ally short-
circuit proof
(regenera-
tion)
The COMBIVERT R6 is conditionally short-circuit proof (EN61800-5-1 /
VDE0160). The intended function is guaranteed after resetting the internal
protection devices.
Exception:
If earth- or short-circuits often occurs at the output, this can lead to a defect
in the unit.
Cyclic acti-
vation and
deactiva-
tion
With applications requiring the COMBIVERT R6 to be switched on and off cycli-
cally, maintain an off-time of at least 5 min. If you require shorter cycle times
please contact KEB.Switching off during the initialization phase can cause un-
denedconditions.
RCD (resid-
ual current
operated
circuit-
breaker)
When using systems with RCD, the instructions or the requirements of VDE
0100-T530(IEC60364-5)mustbeobserved.Therecommendedtrippingcur-
rent of RCD type "B" is 300 mA.
GB - 65
Safety Instructions