Monitoring and analysis parameters
Approach of the working meters
The displayed values of the working meters offer only an estimate value because
of measurement and calculation inaccuracies. These displayed values are un-
suitable for tariff applications and cannot replace any measuring devices.
7.4 Monitoring and analysis parameters
The following parameters serve for the functional monitoring during operation.
No. Name r/w Enter Origin
CP.01 status display ru.00
The status display shows the actual working conditions of the COMBIVERT.
Status Messages
rEGEn Regenerationactive(regenerativeoperation)
bbL Count down of the base-block time, R6-S released
noP „noOperation“controlreleasenotbridged,modulationswitchedoff
nEtoF
Mains power failure; regenerative operation is further possible, if the disconnect-
ingtimeE.nEt(Pn.14)>0s
Stb R6-Sregenerativeunitinstand-byoperation(motoricoperation)
Error Messages
E.dOH
„ERROR!overheatchoke“,temperaturemonitoringofthecommutationchokehas
triggered and the coolong-off period is up.
E. EF „ERROR!externalfault“,errormessagebyanexternalunit
E.FnEt
„ERROR!mainsfrequency",themainsfrequencydeviatesmorethan5%.The
max. mains frequency deviation can be adjusted in the application mode with
CS.03.
E.LSF
ERROR!load-shuntdefectiveorwrongrespectivelyinputvoltagetoolow.This
messageisdisplayedforashorttimeduringthepower-onphase(noerrormes-
sagefollows).
E.nEt „ERRORnet",oneormorephasesaremissing
E.nOH noERRORoverheatpow.mod.(E.OH)notanylongerpresent,errorcanbereset.
E.nOL No Over Load, cooling time after E.OL is up , error can be reset.
E. OC „ERRORovercurrent,outputcurrenttoohighorgroundfault
E. OH „ERRORoverheatpow.mod.“,overheatingatheatsink(see„Technicaldata“)
E.OHI „ERRORoverheatinternal“,temperatureintheinterior>70°C
E. OL „ERRORoverload,overloadmonitoringoftheregenerativeunithasresponded
E. OP „ERRORoverpotential,DClinkvoltagetoohigh
E.PFd „ERRORinitialisation“,powerfailure(phase)duringtheinitialisationphase
E. Pu „ERRORpowerunit“,powerunitcodeismissing,loadshuntrelaydefective
E.Puci „ERRORpow.unitcodeinv.“powerunitcodeisinvalid
E.Puch „ERRORpowerunitchanged“.
continued on the next page

Table of Contents

Other manuals for KEB combivert R6-S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB combivert R6-S and is the answer not in the manual?

KEB combivert R6-S Specifications

General IconGeneral
BrandKEB
Modelcombivert R6-S
CategoryPower Supply
LanguageEnglish

Related product manuals