GB - 99
Special adjustments
No. Name r/w Enter Origin
CP.33 operating mode yes yes Pn.19
This parameter determines the master or slave of regenerative units at parallel connection.
Furtheritisadjustedwhetheraharmoniclteroracommutationchokeisseries-connected.
Single units must be adjusted to master.
Value range Meaning
4 Master-Slave with commutation reactor input selection
5 Master-Slavewithharmoniclterinputselection
No. Name r/w Enter Origin
CP.34 regeneration level yes cS.02
Value range Meaning
100…120 %
The regeneration level determines the starting value to energy regen-
eration. The adjusted value refers to the reference value of the DC
voltageinpercentage.ThestatuschangesfromStandby„Stb“tore-
generation„rEGEn“.