GB - 96
Monitoring and analysis parameters
No. Name r/w Enter Origin
CP.13 active power ru.81
Resolution Meaning
0.1 kW
CP.13 displays the actual power of the COMBIVERT R6-S. Motor pow-
er is displayed with positive values, generatoric power is displayed with
negative values.
No. Name r/w Enter Origin
CP.14 total regen ru.82
Resolution Meaning
1 kW Counter for the regeneratoric electric work to the mains.
No. Name r/w Enter Origin
CP.15 total motor ru.83
Resolution Meaning
1 kW Counter for the supplied electrical work from the mains in kWh.
No. Name r/w Enter Origin
CP.16 total net ru.84
Resolution Meaning
1 kW
Display of the difference between supplied and regeneratoric work.
The result is displayed by right sign.
No. Name r/w Enter Origin
CP.17 actual net ru.85
Resolution Meaning
0.01 kVA Display of the current apparent power at the mains input.