GB - 69
Technical Data
Standard Standard/
class
Instructions
Climate
Temperature
EN 60721-3-3
3K3
extended to -10…45 °C
(withtemperatureover45°Ctomax.55°C
a derating of 5 % per 1 K must be taken into
consideration)
Humidity 3K3 5…85%(withoutcondensation)
Mechanical Vibration
max. amplitude of a vibration 1 mm
(5…13Hz)
max. acceleration amplitude 7 m/s²
(13…200Hz)
3M1
Contamination
Gas 3C2
Solids 3S2
Ambient conditions during transport
Climate
Temperature
EN 60721-3-2
2K3
Humidity 2K3 (withoutcondensation)
Mechanical
Vibration
max.vibrationamplitude3.5mm(2…9Hz)
max.accelerationamplitude15m/s²(9…200Hz)
2M1
Surge 2M1 max. 100 m/s²; 11 ms
Contamination
Gas 2C2
Solids 2S2
Ambient conditions for the storage
Climate
Temperature
EN 60721-3-1
1K4
Humidity 1K3 (withoutcondensation)
Mechanical
Vibration 1M1
max. amplitude of a vibration 1 mm
(5…13Hz)
max.accelerationamplitude7m/s²(13…200Hz)
Surge 1M1 max. 100 m/s²; 11 ms
Contamination
Gas 1C2
Solids 1S2
Type of protection EN 60529 IP20
Environment IEC 664-1 Pollution degree 2
Denitionaccordingto EN 61800-3 Inverterproductstandard:EMC
EMC emitted interference
Cable-based interferences – C2 withlter(onlywithferriterings)
Radiated interferences – C2 withlter(onlywithferriterings)
Interference immunity
Electro-static discharge EN 61000-4-2 8 kV AD(airdischarge)andCD(contactdis-
charge)
Burst - control lines + bus EN 61000-4-4 2 kV
Burst - mains supply EN 61000-4-4 4 kV
Surge - mains supply EN 61000-4-5 1 / 2 kV Phase-phase / phase-ground
Immunity to conducted
disturbances,
induced by radio-frequency
elds
EN 61000-4-6 10 V 0.15-80 MHz
Electromagneticelds EN 61000-4-3 10 V/m
Voltage variation/
voltage drop
EN 61000-2-1 +10 %, -15 %; 90 %
Voltage unsymmetries/
frequency changes
EN 61000-2-4 3 %; 2 %