X5 FastMig
Operating manual - EN
MMA settings
The parameters listed here are available for adjustment with the MMA process.
Parameter Parameter value Description
Hot start
Min/Max = -30 ... +30, step 1
Default = 0
Welding function that uses higher or
lower welding current at the start of the
weld. During the Hot start period the cur-
rent changes to the normal welding cur-
rent level. The Hot start value affects the
current level and duration. Use it to pre-
vent the electrode from sticking to the
work piece.
VRD
OFF/12V/24V
Default = OFF
Voltage reduction device (VRD) reduces
the open-circuit voltage to maintain
below a certain voltage value.
Current limit min
Min/Max = 10 ... machine size A, step 1
Default = 10 A
Minimum and maximum limits for the
current adjustment.
Current limit max
Min/Max = 10 ... machine size A, step 1
Default = 10 A
Common settings
The parameters listed here are common system settings.
Parameter Parameter value Description
Weld data
Min/Max = 0 ... 10 s, step 1
0 = OFF
Default = 5 s
This defines how long the weld data sum-
mary is shown after each weld.
Display off
Min/Max = 5 ... 120 min, step 1
Default = 5 min
Not available with MMA or gouging.
Date
Current date Adjusting date:
Select day by pressing the knob key
Adjust day by rotating the knob
(Min/Max = 1...28/29/30/31)
Select month by pressing the knob key
Adjust month by rotating the knob
(Min/Max = 1...12)
Select year by pressing the knob key
Adjust year by rotating the knob
(Min/Max = 2000...2099)
Press the knob key to end adjustment.
Time
Current time Adjusting time:
Select hours by pressing the knob key
Adjust hours by rotating the knob
(Min/Max = 0...23)
Select minutes by pressing the knob key
Adjust minutes by rotating the knob
(Min/Max = 0...59)
Press the knob key to end adjustment.
Time counter total
>>> This shows the total arc time and power
on time.
Time counter since
>>> This shows the total arc time and power
on time since the last reset.