EasyManua.ls Logo

Keysight Technologies E8257D - A25 B Highband Detector Bias Board; Tools Required; Removal Procedure; Replacement Procedure

Keysight Technologies E8257D
417 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
332 E8257D/67D, E8663D PSG Signal Generators Service Guide
Assembly Replacement
A25B Highband Detector Bias Board
A25B Highband Detector Bias Board
Tools Required
T–10 driver
Removal Procedure
Refer to Figure 3-45 for this procedure.
1. Disconnect the power cord.
2. Remove the covers from the signal generator. Refer to “Outer Instrument
Cover” on page 258 and Inner Instrument Cover” on page 260.
3. Position the signal generator with the A31 Motherboard facing away from
you and the RF deck on top.
4. Disconnect the A25BW1 bias board power cable from the A26 MID J12.
5. Using the T–10 driver, remove the two screws (1) that attach the A25B
Highband Detector Bias Board to the A24 Highband Coupler.
6. Remove the A25B Highband Detector Bias Board.
Replacement Procedure
Reverse the order of the removal procedure.
Torque all T–10 screws to 9 in–lbs.
Perform the post–repair adjustments and performance tests that pertain to
this removal procedure.

Table of Contents