123
Key Reference
Meas
ACPR
Adjacent Channel Power Ratio (ACPR) measures the power
present in adjacent transmit channels. The span is
automatically set according to the six available offsets and
their associated integration bandwidths as defined by the
user.
Center Freq Sets the center frequency of the main channel power.
Key access: Meas > ACP
Main Channel Specifies the range of integration used in calculating the
power in the main channel. Use the knob, the arrow keys, or
the numeric keypad to set the bandwidth.
Key access:
Meas > ACP
Adjacent Chn
State
Press Adjacent Chn to choose the number of the adjacent
channel. There are optional 6 adjacent channels. Press
adjacent Chn State to turn on/off each adjacent channel power
display.
Key access: Meas > ACP
Adjacent
Channel BW
Specifies the range of integration used in calculating the
power in the adjacent channel. Use the knob, the arrow keys,
or the numeric keypad to set the bandwidth.
Key access: Meas > ACP
Adj Chn Space Sets the space value between the center frequency of main
channel power and that of the adjacent channel power.
Key access: Meas > ACP
RRC Filter This softkey is a combined key to set the Root- Raised Cosine
filter state and the filter Alpha value. When the filter is set
to On, there will be an annotation ā€œRRC ONā€ on the display.
Key access: Meas > ACP
Filter BW Press this softkey to set the filter bandwidth of the RRC
filter. The default value is the integrated bandwidth.
Key access: Meas > ACP