EasyManua.ls Logo

Keysight Technologies N9322C - Page 73

Keysight Technologies N9322C
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
Functions and Measurements
Channel Scanner
3 Press Meas > Scan Mode > Top N to set the scan mode to
TOP N channel mode. Input the channel number you need
to monitoring. Press Enter as a terminator.
4 Press Range Edit to access the submenu to edit the scan
range.
Toggle Edit Method to underline Std. It allows you to set the
range according to the embedded communication standard,
such as CDMA and GSM which is used specifically in
different countries. Press Signal Std to select the standard.
Press Recall as a terminator. Press Begin Chn and End Chn to
set the begin and end channel for scanning. Press Apply to
apply all the range settings.
If you toggle Edit Method to underline Custom, it allows you
to set the customer- defined scan as your need.
Press Start Freq to set the scan start frequency.
Press Freq Step Size to set the frequency interval for
adjacent channels.
Press Bandwidth to set the bandwidth of each frequency
channel which is used to calculate the channel power.
Press Number of Chn to set the number of frequency
channels which will be scanned.
Press Apply as a terminator to apply all the settings above.
5 Press Scan Start to initiate the channel scan function.
6 Press Logging Start to start recording the scan process
which includes the channel power and related channel
bandwidth value to a CSV file. Press Logging Stop to end
the logging. The CSVfile will be saved immediately.