34 Keysight N774xC Series Multiport Power Meter Programming Guide
3 Instrument Setup and Status
Status Reporting The STATus Subsystem
The Status subsystem allows you to return and set details from the Status
Model.
Command: :STATus:OPERation[:EVENt]?
Syntax: :STATus:OPERation[:EVENt]?
Description: Returns the Operational Status Event Summary Register (OSESR).
Parameters: none
Response: The sum of the results for the Channels (a 16-bit unsigned integer value, where 0 value 65535):
Bits Mnemonics Decimal Value
N7744C N7745C
9-15 Not used Not used
8 Not used Channel 8 Summary 256
7 Not used Channel 7 Summary 128
6 Not used Channel 6 Summary 64
5 Not used Channel 5 Summary 32
4 Channel 4 Summary Channel 4 Summary 16
3 Channel 3 Summary Channel 3 Summary 8
2 Channel 2 Summary Channel 2 Summary 4
1 Channel 1 Summary Channel 1 Summary 2
0 Not used Not used 1
Example: :stat:oper? -> +0
Command: :STATus:OPERation:CONDition?
Syntax: :STATus:OPERation:CONDition?
Description: Reads the Operational Status Condition Summary Register.
Parameters: none