Keysight N774xC Series Multiport Power Meter Programming Guide 37
Instrument Setup and Status 3
Command: :STATus[n]:OPERation:ENABle
Syntax: :STATus[n]:OPERation:ENABle<wsp><value>
Description: Sets the bits in the Operation Slot Status Enable Mask (OSSEM) for slot n that enable the contents of the Operation Slot
Status Event Register (OSSER) for slot n to affect the OSESR.
Setting a bit in this register to 1 enables the corresponding bit in the OSSER for slot n to affect bit n of the OSESR.
Parameters: The bit value for the OSSEM as a 16-bit unsigned integer value (0 .. +65535)
Response: none
Example: :stat0:oper:enab 128
Command: :STATus[n]:OPERation:ENABle?
Syntax: :STATus[n]:OPERation:ENABle?
Description: Returns the OSSEM of slot n
Parameters: none
Response: The bit value for the OSSEM as a 16-bit unsigned integer value (0 .. +65535)
Example: :stat0:oper:enab? -> +128
Command: :STATus:PRESet
Syntax: :STATus:PRESet
Description: Presets all bits in all OPERation and QUEStionable status systems to 0.
Parameters: none
Response: none
Example: :stat:pres
Command: :STATus:QUEStionable[:EVENt]?
Syntax: :STATus:QUEStionable[:EVENt]?
Description: Returns the Questionable Status Event Summary Register (QSESR).

Table of Contents

Other manuals for Keysight N774 C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight N774 C Series and is the answer not in the manual?

Keysight N774 C Series Specifications

General IconGeneral
BrandKeysight
ModelN774 C Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals