EasyManuals Logo

Kikusui PLZ-U Series User Manual

Kikusui PLZ-U Series
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
6-30 Remote Control PLZ-U
PROG:FSP:END
Sets the end step of the sequence mode.
Set command: PRGram[:SELected]:FSPeed[:STEP]:END
<step>
Query command: PRGram[:SELected]:FSPeed[:STEP]:END?
Program data <step>
Value 1 to 255
Resolution 1
Example) When step 1 to step 5 are looped
PROG:FSP:END 6
PROG:FSP:EDIT
Edits an existing sequence step. Or, queries the current setting.
If the parameter is omitted, the current value is retained.
Set command: PRGram[:SELected]:FSPeed[:STEP]:EDIT
[:POINt] <step>,{<conductance>
|<current>}],[<trig>],<time>
Query command: PRGram[:SELected]:FSPeed[:STEP]
:EDIT[:POINt]? <step>
Program data <trig>
Value 0: Always enter 0 for the value, because the PLZ-U is
not equipped with trigger output.
Returns the current value of the <step> as {<conductance>|<current>},0,<time> in
response to PROG:FSP:EDIT? <step>.
Example) If the current value is 9.876 A in the H range of CC mode and the execu-
tion time is 1.234 s in step 5
Returns 9.876,0,1.234 in response to PROG:FSP:EDIT? 5.

Table of Contents

Other manuals for Kikusui PLZ-U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kikusui PLZ-U Series and is the answer not in the manual?

Kikusui PLZ-U Series Specifications

General IconGeneral
BrandKikusui
ModelPLZ-U Series
CategoryControl Unit
LanguageEnglish

Related product manuals