(1) Double Acting Valve Lever
(A) Port “A” (Single Acting) (B) Port “B”
U26o747a
EXTERIOR HYDRAULIC CONTROL SYSTEM (IF EQUIPED)
DOUBLE ACTING VALVE LEVER
KIOTI supplies two types of the
double acting valves by region: self-
return type and detent type.
For the self-return type double
acting lever, it returns to its neutral
positiontoblockthehydraulicuid
when it is pushed/pulled and then
released. Therefore, this type of
double acting valve lever should
be pulled or pushed continuously
for operation which is suitable for
an implement with a short operat-
ing time, such as a hydraulic cylin-
der.
For the detent type double act
-
ing valve lever, it keeps its posi-
tion after it is pulled or pushed to
a certain position. Therefore, it is
not necessary to hold the lever to
a certain position which is suitable
for an implement with a long op-
erating time, such as a hydraulic
motor.
Pressure
Returning
Port A, B, C, D
Coupler Size
½ inch
Port Push Pull
Lever 1
A In Out
B Out In
Lever 2
C In Out