Hook suspendeed Type:ER2
Manual Trolley type:ER2SP/ER2SG
Motorized Trolley type:ER2M
Permissible length (m) = ×
1000
30.8
Cross section of one core (mm
2
)×Rated voltage (V)×0.02
Rated current (A)
Do not use the cable other than the cable attached to the Body size or optional Power Cable.
Failure to comply with this instruction causes bodily injury or loss of property.
Prohibited
Satisfy the maximum permissible length and core cross section of the Power Cable.
Failure to comply with this instruction causes bodily injury or loss of property.
Mandatory
CAUTION
Refer to the following table for the permissible length and the size of the standard Power Cable.
When using the cable of the size other than those described in the table, decide the cable length using the following
formula.
(to be continued)
Assembling Checking Power and Power Cable
1
Code
Wire
size
(mm
2
)
230V Class 400V Class
Single speed Dual speed Single speed Dual speed Single Dual
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz
220-230V 380-415V 380-440V 380-415V 380-440V
415V
ER2-001H/IH
1.25
(2)
46
(75)
59
(95)
44
(71)
123
(197)
171
(118)
114
(182)
134
(215)
124
(199)
ER2-003S/IS
ER2-005L/IL
ER2-003H/IH
35
(57)
41
(66)
33
(53)
90
(144)
118
(189)
85
(136)
98
(158)
93
(149)
ER2-005S/IS
ER2-010L/IL
ER2-010S/IS
24
(39)
21
(34)
20
(32)
64
(102)
66
(107)
60
(96)
70
(112)
65
(105)
ER2-016S/IS
ER2-020L/IL
ER2-020S/IS
2
(3.5)
21
(37)
18
(32)
17
(30)
59
(103)
56
(99)
53
(93)
40
(64)
36
(58)
ER2-025S/IS
ER2-032S/IS
ER2-050S/IS
Code
Wire
size
(mm
2
)
230V Class 400V Class
ER single
MR single
ER dual
MR dual
ER dual
MR single
ER single
MR dual
ER single
MR single
ER dual
MR dual
ER dual
MR single
ER single
MR dual
ER
single
MR
single
ER
dual
MR
dual
ER
dual
MR
single
ER
single
MR
dual
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz
220-230V
380-
415V
380-
440V
380-
415V
380-
440V
380-
415V
380-
440V
380-
415V
380-
440V
415V
ER2-001H/IH
2
(3.5)
40
(70)
47
(83)
38
(66)
39
(68)
40
(71)
39
(68)
43
(76)
102
(179)
123
(215)
94
(165)
98
(172)
100
(175)
98
(172)
114
(200)
112
(196)
103
(181)
107
(188)
107
(88)
ER2-003S/IS
ER2-005L/IL
ER2-003H/IH
34
(60)
39
(68)
32
(56)
33
(58)
34
(60)
33
(58)
36
(64)
86
(151)
102
(179)
80
(141)
83
(146)
84
(148)
83
(146)
96
(169)
94
(165)
88
(154)
91
(159)
91
(159)
ER2-005S/IS
ER2-010L/IL
ER2-010S/IS
26
(47)
25
(44)
23
(40)
23
(41)
24
(42)
26
(46)
24
(42)
69
(121)
72
(126)
64
(113)
66
(116)
67
(118)
67
(118)
69
(118)
75
(132)
70
(123)
72
(127)
73
(128)
ER2-016S/IS
ER2-020L/IL
ER2-020S/IS
3.5
(5.5)
30
(47)
27
(42)
25
(39)
25
(40)
26
(40)
29
(46)
26
(41)
81
(127)
79
(124)
73
(115)
74
(117)
75
(118)
79
(125)
77
(120)
50
(88)
46
(80)
46
(81)
49
(87)
ER2-025S/IS
ER2-032S/IS
ER2-050S/IS
27
(42)
24
(38)
23
(36)
23
(36)
23
(37)
26
(41)
24
(37)
71
(111)
71
(112)
65
(102)
66
(104)
68
(108)
70
(110)
69
(106)
44
(77)
40
(71)
41
(72)
43
(76)
Checking the Power Cable
(Unit: m)
(Unit: m)

Table of Contents

Other manuals for KITO ER2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KITO ER2 Series and is the answer not in the manual?

KITO ER2 Series Specifications

General IconGeneral
Control Voltage24V
Duty Cycle40% ED
Protection ClassIP55
Temperature Range-20°C to +40°C
TypeElectric Chain Hoist
Frequency50/60 Hz
Motor InsulationClass F
Brake TypeElectromagnetic
Load Chain GradeGrade 80
Ambient Temperature-20°C to +40°C
Power Supply3-phase
Lift Height3 to 30 meters
Chain Falls1 or 2
Voltage200-240V, 380-480V