61
Check after Installation
Check items
Make sure that the following are satisfied:
• No bolt, nut nor split pin is lost. Tightening and assembling are completed.
• Protection Wire for Push Button Switch Cord is securely tied to accept and endure the force instead of Push
Button Switch Cord when the Push Button Switch Set is drawn.
• The Power Cable is fixed to the Cable Support.
• Source voltage is the rated voltage
• Grounding Wire (earth wire) is connected securely.
When using with a Trolley
Check the following:
• The electric chain hoist and the trolley are combined correctly.
• The stoppers for trolley are securely mounted to Travel Rail where the Trolley travels.
• The surface of Travel Rail is not attached with paint or oil. (The surface of the Travel Rail must be basis metal. Do
not paint.) There is no obstacle for the trolley to travel. The Travel Rail is set to a level.)
Operational Check
Carry out the operational check in accordance with Daily inspection (P20).
Wrong assembling or installation causes death or serious injury. To prevent such danger check the following.
Check after Installation
1

Table of Contents

Other manuals for KITO ER2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KITO ER2 Series and is the answer not in the manual?

KITO ER2 Series Specifications

General IconGeneral
Control Voltage24V
Duty Cycle40% ED
Protection ClassIP55
Temperature Range-20°C to +40°C
TypeElectric Chain Hoist
Frequency50/60 Hz
Motor InsulationClass F
Brake TypeElectromagnetic
Load Chain GradeGrade 80
Ambient Temperature-20°C to +40°C
Power Supply3-phase
Lift Height3 to 30 meters
Chain Falls1 or 2
Voltage200-240V, 380-480V

Related product manuals