EasyManuals Logo

Kleemann GENIUS20 User Manual

Default Icon
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
109
MA06-03-1-01
Menu
[Direct access: CMD -> 7087]
Parameter
[Direct access]
Description
Default
value
Value Range
Fix floor
Definition of the fixed parking landing’s
number.
0
(=deactivat
ed)
0-max. landings
Main stop parking
Query whether the lift is to park in the main
landing.
NO
YES/NO
Decided by
ΚΜGroup
Query whether the distribution for parking
this system is to be made by the group
controller.
NO
YES/NO
T: Parking time(s)
Definition of the time interval necessary for
approaching the parking landing. When this
time has elapsed - after the last travel - the
lift goes to the parking position.
0-999 s
Door open in park
floor
Query whether the doors are to be opened
after having approached the destination
parking landing.
NO
YES/NO