3 Parameter description
The GENIUS20 parameters are distributed to internal pages. To edit or view the values, use the menu
navigation or direct access the associated pages.
Call the required page by entering 7 plus the three-digit page number (e.g. page 60: CMD -> 7060 ->
OK).
Parameters
Due to the variety of the different cases in the "Parameter" section we have introduced a sub-menu
for parameters. All parameters are accessible from here.
[Direct access: CMD -> 7057-> OK]
This parameter menu is divided into:
❑ "General settings" like number of landings, frequency inverter, landing height, building
accesses, scrolling texts, etc.
❑ Configuration regarding "Doors" like times, accesses, door signals, etc.
❑ Parameterisation of "Input / Output" for door sides, car, control cabinet and general
controller values.
❑ The "Mode" subsection serves to configure operating states for normal travel, various
possible special travels, fire emergency, visitor control, hold to run, etc.
❑ "Special" is used to set the language, time and several special functions.